TOP > Discontinued Models > MS31i2




World’s
First 3MP-based Display FDA Cleared for Digital Mammography .... |
3MP with ISD Technology
21.3" Digital Mammography Display
3MP-based Display for Digital Mammography
Digital mammography viewing demands an extraordinarily high level of precision
from your LCD display. Totoku's MS31i2 redefines new standards of care by over-delivering
resolution and clarity for improved accuracy in breast cancer screening.
With
integrated ISD (Independent Sub-pixel Drive) technology, the MS31i2 exceeds
resolution values of traditional 5 Mega-pixel displays, and due to economies
of scale, is more affordable than its 5 megapixel counterpart. Introducing
the MS31i2, with ISD technology enables a 3Mega-pixel-based LCD to render 9
mega sub-pixel images, exceeding the current standards of care for primary
mammography diagnosis. The MS31i2 is FDA (510K) cleared for the use of Digital
Mammography.
|
Features
High resolution of 9M sub-pixels realized by ISD
technology
Faithful Reproduction of Image Details
While a pixel pitch of 3MP display is 210µm,
MS31i2 achieves
70µm in sub-pixel chain direction by newly developed ISD technology to realize excellent
depiction of image details.
Advanced Image Quality with Less Degradation
To display an overall image whose native resolution is higher than the monitor
is able to reproduce, the image is converted to a lower resolution image with
a certain amount of data loss.
The MS31i2 with high resolution offers excellent image reproduction,
faithful to the original captured by the modality device with less image degradation.
ISD (Independent Sub-pixel Drive) Technology
Driven by each sub-pixel value corresponding to detailed
information recorded in an original image, three times resolution enhancement
is achieved. (Patent pending)
In addition, up to 1276 shades of gray are now simultaneously displayable by
the upgraded ISD technology.
*Customized viewer software is required to display images with enhanced resolution
by the ISD technology.

3MP-based
display with the ISD technology performs either equaling or surpassing
the 5MP's
Comparison between 9 MsP and 5 MP
Visibility comparison
Visibility
comparison of existence and shape evaluation of microcalcifications (MCLs),
using 50 clinical cases obtained by a digital mammography system (pixel size:
70um).
Scoring method for 9MsP superiority
The most of cases were rated as "Equivalent",
and 23% were answered as "Better". Our study indicated that the potential performance of the 9MsP LCD
was equivalent to or better than the conventional 5MP LCD for evaluating
very
small MCLs and interpreting clinical digital mammography with various types
of MCLs.
Note:
Display magnification % was adjusted freely by each observer.
Source:
Comparative Study between 9 Mega-sub-Pixel and 5 Mega-Pixel LCDs
using Simulated Microcalcification images and Clinical Mammograhy (RSNA2009)
Katsuhiro Ichikawa Ph. D1), Hiroko Kawashima, MD 1), Aya Nishimura 2),
Mikio Hasegawa 3), Naohiro Kimura 3)
1) Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University,
2) Kanazawa University, hospital, 3) TOTOKU Electric Co., Ltd.
Visual Detection study using images of 0.15mm simulated microcalcification
This chart shows relationship magnifications and dectablility for the
9MsP and the 5MP's where the 9MsP exceeds 5MP
in detectability.

Source:
Title: Clinical Usefulness of Super High-Resolution Liquid Crystal Displays Using
Independent Sub-pixel Driving Technology
International Workshop on Digital Mammography (IWDM) 2008 August 2008,
THE UNIVERSITY OF ARIZONA, U.S.A
Katsuhiro Ichikawa 1), Hiroko Kawashima 2), Naohiro Kimura 3), and Mikio Hasegawa 3)
1) Graduate School of Medical Science, Kanazawa University,
2) Department of Radiology, Kanazawa University Hospital,
3) Totoku Electric Co., Ltd.
|
Special AR Coating for Film-like Black and Improved Sharpness
TOTOKU's new special AR coating technology addresses properties of focus, noise
reduction, contrast, and viewing angle achieving film-like black and accurate
reproduction of images. (Patent pending)

Simultaneous display of 1276 shades of gray
Realizes smoother grayscale display required for medical image displays.
New luminance stabilizing system λ-Sentinel
II
λ-Sentinel II consists of a luminance sensor and luminance control circuit. The
luminance sensor, integrated into the front bezel, consistently monitors and
accurately stabilizes luminance on the screen by rapidly communicating with
the backlight sensor.
In addition, a build-in luminance sensor provided with i2 models enables
even simpler calibration without attaching the calibration sensor.

Remote grayscale check and remote calibration functions
Conformance testing to DICOM GSDF and calibration can be remotely accomplished.
These features minimize the burden on display administrators.
* Optional PM Medivisor software is required.

Luminance equalizer λ-Uniformity Congruence
Is built in to achieve highly accurate luminance uniformity across the screen. Luminance unevenness is minimized in the final tune-up prior to shipping.
* Images shown are for illustrative purposes only.
Calibration
function
Calibrates
luminance and gamma to enable smooth grayscale display that is faithful to
DICOM GSDF.
* Optional calibration kit is required.

Hardware pivot function for fast drawing in portrait on landscape orientation
Stress-free operation is made possible by fast drawing speed for on-the-fly change
to portrait.
OSD Information Display
With a push of a button, the display's current status can be checked such as
the display model, total operating time, actual measurement of luminance, and
calibration settings.
LED indicator to inform of current status
A glance at the LED indicator tells you the display's current operating status.

Enhanced convenience with utility software:
Advanced power saving*
The backlight dims as the screensaver starts, reducing power consumption and
preventing unnecessary deterioration of the backlight.
* This feature may not be available, depending on the specifications of the graphics card used.
Gamma check
18 points of luminance values are measured and plotted into a graph.
Ambient light and display luminance measurement
The built-in sensors measure display luminance
and ambient illuminance.
Pairing service to match colors of two displays (Optional)
Worldwide medical safety standards
This display is certified under various medical safety standards that are much more demanding than those for general-purpose IT equipment.
Specifications & Dimensions
Specifications
Model Name |
MS31i2 |
LCD Panel |
Technology |
21.3-inch, Monochrome, TFT active matrix IPS Technology |
Display Area |
433mm x 325mm |
Pixel Pitch |
0.2115mm x 0.2115mm |
Contrast Ratio |
900:1 (typ) |
Maximum Luminance |
1450cd/m² (typ), (calibrated to 410cd/m²) |
Viewing Angle |
170° horizontal and vertical (typ) |
Visual Performance |
Available Resolution |
1536 X 2048, ISD ON: 1536 X 6144(sub-pixel)
*MS31i2 supports 9M-ISD and 3M-normal modes.
To use MS31i2 in 9M-ISD mode, customized viewer software is required. |
Grayscale |
3061 shades of gray to 256 shades of gray
Simultaneous display of 1276 shades of gray is possible with the customized viewer. |
Input Signal |
Input Sync Signal |
DVI 1.0 compliant |
Plug and Play |
DDC2B compliant |
Input Power Supply |
Input |
AC Adapter 100V-240V (±10%) 50/60Hz |
Maximum Power Consumption |
95W (typ), (with power management feature) |
Features |
Calibration Control |
Luminance, Gamma, Capability of saving 3 sets of LUT settings (An optional calibration
kit is required.) |
OSD Information Display |
Model name, Serial No., Total operating time, Calibration settings (Operating time from Last Calibration, Luminance, Gamma, etc.), Current luminance, etc. |
USB Hub |
USB Rev. 2.0 compliant, Self-powered
USB upstream connector (x1), USB downstream connector (x2) |
Other Features |
Luminance Uniformity Correction Function, Hardware Pivot function,
LED indicator |
Standards |
UL60601-1, CSA C22.2 No. 601.1, MDD/CE, FCC-B, VCCI-B , FDA510(k) |
Physical Characteristics |
Dimensions (WxHxD) |
Landscape : 474.0 (W) X 468.4 / 529.9 (H) X 220.0 (D) mm
Portrait : 367.0 (W) X 521.9 / 583.4 (H) X 220.0 (D) mm |
Weight |
Net: approx. 11.2kg, Without tiltstand: approx. 7.0kg |
Tilt Stand |
Tilt, Swivel, Portrait / Landscape |
Mount |
100mm VESA compliant |
Security Slot |
On the back of the panel and the tilt stand |
LCD surface treatment |
Special AR coating |
Accessories |
AC adapter, Power cord (3P), DVI cable, USB cable, User manual |
Dimensions
Option
Pairing service to match colors of two displays
Details
Page Top |