TOP > Discontinued Models > MS31i2
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() World’s First 3MP-based Display FDA Cleared for Digital Mammography .... |
3MP with ISD Technology 21.3" Digital Mammography Display
3MP-based Display for Digital Mammography Digital mammography viewing demands an extraordinarily high level of precision
from your LCD display. Totoku's MS31i2 redefines new standards of care by over-delivering
resolution and clarity for improved accuracy in breast cancer screening. |
High resolution of 9M sub-pixels realized by ISDFaithful Reproduction of Image Details
While a pixel pitch of 3MP display is 210µm,
MS31i2 achieves
70µm in sub-pixel chain direction by newly developed ISD technology to realize excellent
depiction of image details.
Advanced Image Quality with Less Degradation
To display an overall image whose native resolution is higher than the monitor
is able to reproduce, the image is converted to a lower resolution image with
a certain amount of data loss.
The MS31i2 with high resolution offers excellent image reproduction,
faithful to the original captured by the modality device with less image degradation.
ISD (Independent Sub-pixel Drive) Technology
Driven by each sub-pixel value corresponding to detailed
information recorded in an original image, three times resolution enhancement
is achieved. (Patent pending)
In addition, up to 1276 shades of gray are now simultaneously displayable by
the upgraded ISD technology.
*Customized viewer software is required to display images with enhanced resolution
by the ISD technology.
| 3MP-based
display with the ISD technology performs either equaling or surpassing
the 5MP's Visibility comparison Scoring method for 9MsP superiority
Note: Source:
Visual Detection study using images of 0.15mm simulated microcalcification ![]() Source: |
|---|
TOTOKU's new special AR coating technology addresses properties of focus, noise reduction, contrast, and viewing angle achieving film-like black and accurate reproduction of images. (Patent pending)
Simultaneous display of 1276 shades of grayRealizes smoother grayscale display required for medical image displays.
New luminance stabilizing system λ-Sentinel
IIλ-Sentinel II consists of a luminance sensor and luminance control circuit. The
luminance sensor, integrated into the front bezel, consistently monitors and
accurately stabilizes luminance on the screen by rapidly communicating with
the backlight sensor.
In addition, a build-in luminance sensor provided with i2 models enables
even simpler calibration without attaching the calibration sensor.
Remote grayscale check and remote calibration functionsConformance testing to DICOM GSDF and calibration can be remotely accomplished. These features minimize the burden on display administrators.
* Optional PM Medivisor software is required.
Luminance equalizer λ-Uniformity CongruenceIs built in to achieve highly accurate luminance uniformity across the screen. Luminance unevenness is minimized in the final tune-up prior to shipping.
* Images shown are for illustrative purposes only.
Calibrates
luminance and gamma to enable smooth grayscale display that is faithful to
DICOM GSDF.
* Optional calibration kit is required.
Stress-free operation is made possible by fast drawing speed for on-the-fly change to portrait.
OSD Information DisplayWith a push of a button, the display's current status can be checked such as the display model, total operating time, actual measurement of luminance, and calibration settings.
LED indicator to inform of current statusA glance at the LED indicator tells you the display's current operating status.
This display is certified under various medical safety standards that are much more demanding than those for general-purpose IT equipment.
| Model Name | MS31i2 | |
|---|---|---|
| LCD Panel | Technology | 21.3-inch, Monochrome, TFT active matrix IPS Technology |
| Display Area | 433mm x 325mm | |
| Pixel Pitch | 0.2115mm x 0.2115mm | |
| Contrast Ratio | 900:1 (typ) | |
| Maximum Luminance | 1450cd/m² (typ), (calibrated to 410cd/m²) | |
| Viewing Angle | 170° horizontal and vertical (typ) | |
| Visual Performance | Available Resolution | 1536 X 2048, ISD ON: 1536 X 6144(sub-pixel) *MS31i2 supports 9M-ISD and 3M-normal modes. To use MS31i2 in 9M-ISD mode, customized viewer software is required. |
| Grayscale | 3061 shades of gray to 256 shades of gray Simultaneous display of 1276 shades of gray is possible with the customized viewer. |
|
| Input Signal | Input Sync Signal | DVI 1.0 compliant |
| Plug and Play | DDC2B compliant | |
| Input Power Supply | Input | AC Adapter 100V-240V (±10%) 50/60Hz |
| Maximum Power Consumption | 95W (typ), (with power management feature) | |
| Features | Calibration Control | Luminance, Gamma, Capability of saving 3 sets of LUT settings (An optional calibration kit is required.) |
| OSD Information Display | Model name, Serial No., Total operating time, Calibration settings (Operating time from Last Calibration, Luminance, Gamma, etc.), Current luminance, etc. | |
| USB Hub | USB Rev. 2.0 compliant, Self-powered USB upstream connector (x1), USB downstream connector (x2) |
|
| Other Features | Luminance Uniformity Correction Function, Hardware Pivot function, LED indicator | |
| Standards | UL60601-1, CSA C22.2 No. 601.1, MDD/CE, FCC-B, VCCI-B , FDA510(k) | |
| Physical Characteristics | Dimensions (WxHxD) | Landscape : 474.0 (W) X 468.4 / 529.9 (H) X 220.0 (D) mm Portrait : 367.0 (W) X 521.9 / 583.4 (H) X 220.0 (D) mm |
| Weight | Net: approx. 11.2kg, Without tiltstand: approx. 7.0kg | |
| Tilt Stand | Tilt, Swivel, Portrait / Landscape | |
| Mount | 100mm VESA compliant | |
| Security Slot | On the back of the panel and the tilt stand | |
| LCD surface treatment | Special AR coating | |
| Accessories | AC adapter, Power cord (3P), DVI cable, USB cable, User manual | |
![]() |